Netatmo home| Controls the heating mode of a Netatmo home (thermostat, radiator valves, OpenTherm) and selects the heating schedule. Additionally shows how many persons the cameras recognised as at home. One block per home. Individual rooms are controlled by the block Netatmo room. |
Inputs |
||
| MO |
Heating mode |
0 = schedule, 1 = away, 2 = frost guard. Other values are ignored. Acts when the value changes. During the first seconds after the controller starts the value is only stored and not sent, so that a restart does not overwrite settings made in the Netatmo app. Optional. Not connected: nothing is ever sent. |
| DA |
Duration min |
Duration in minutes for away and frost guard, read when the heating mode changes. Optional. Not connected or 0: the mode applies until it is changed again. |
| ZP |
Schedule number |
Activates the heating schedule with this number (1 = first heating schedule in the Netatmo app). 0 changes nothing. Acts when the value changes. During the first seconds after the controller starts the value is only stored and not sent, so that a restart does not overwrite settings made in the Netatmo app. Optional. Not connected: nothing is ever sent. |
Outputs |
||
| MO |
Heating mode |
0 = schedule, 1 = away, 2 = frost guard, 3 = off. |
| ZN |
Schedule |
Name of the active heating schedule. |
| ZP |
Schedule number |
Number of the active heating schedule (1 = first), 0 = none. |
| PE |
Persons at home |
Number of persons a Netatmo camera lists as present. Without a Welcome camera 0. |
| DA |
Data current |
1 = Netatmo renewed the values within the timeout. 0 = no data since start, account not signed in or timeout expired. |
Parameters |
||
| Account |
Optional. The Netatmo account block used to query this device. The selection is only shown when the project contains several accounts. Not set: the first account in the project. |
|
| Select device |
Opens the list of devices the account found at Netatmo, filtered to the devices that fit this block. The selection sets device name and device ID. The Studio must be connected to the controller and the account signed in. |
|
| Device name |
Name of the device at Netatmo, for display only. |
|
| Device ID |
Netatmo identifier of the device, room or home. Can also be entered manually. Empty: the block delivers no values and shows »Device?«. |
|
| Timeout data outdated |
If no new data arrives from Netatmo within this time (minutes), »Data current« drops to 0. The other outputs keep their last known value. 0 = never outdated. Default 30 min. |
|